In detail
The FireChill ALT500 brings the exciting ability to capture waste heat to the entry level sub-50RT end of the market. Based on FireChill’s AC500, the ALT delivers a step change in fuel efficiency by enabling the ALT to attach simply to an alternate heat source, typically a gas-fired generator. Savings on energy can be significant. Where the ALT is fired entirely by waste heat, energy costs are effectively reduced to zero.
Addition of the ALT to a conventional CHP set-up delivers tri-generation, or CCHP, allowing the simultaneous delivery of heating, cooling and power from one system.
Dual mode
In instances where heat from the alternate waste heat source is either intermittent or of insufficient grade, the ALT’s unique dual mode capability allows users to supplement low grade alternate heat provision with direct-fired gas to maintain consistent cooling output levels. Through dual moding the whole range of heat input profiles, from 100% waste heat to 100% direct-fired and every point in between, is thereby enabled.
Making connections
Direct connection to the turbine exhaust simplifies the system design and eliminates the need for intermediate heat exchangers and other hardware that increase installation costs and degrade performance. The sophisticated on board control systems within the ALT allows it to integrate and communicate readily with other control environments.
Scaling to meet demand
As with the AC, the ALT500 readily scales up via the FireChill MultiPack product to deliver increased cooling load up to 30RT (105kw). Where it combines with a Capstone 30 or 65, then a configuration of two or four is the most appropriate. See the section on MultiPack
Basic fact pack
- Output: 5 Refrigeration Tons (RT) or 17.6kw
- Output temp: 7°C
- Space cooled: 250m² (@30°C)
- Ambient operating temp: 15°C to 53°C
- Coefficient of Performance: (CoP): 0.68
- Power: 208/230V 50Hz or 60Hz – single phase
- Weight: 475kg
- Dimensions: 144(h) x 86 (d) x 139 (w)
Operational benefits save money and improve efficiency
- Saves money through waste heat capture
- Reduces environmental heat emissions
- Saves up to 100% of fuel costs
- Reduced demand charges
- Simplified zone control
- Low power requirement (1.25kw)
- Ideal for peak shaving
- Integrates to building management systems
- No capacity loss overtime
Service and installation benefits reduce costs and saves money
- Configured off-site and pre-tested for ease of installation
- Install and test in a day
- Single point utility connection
- Easy service access from single front panel
- High quality and reliability, less maintenance
- Sealed systems, fewer moving parts, less noise/vibration
- No compressor unit to maintain and replace
- No cooling tower reduces maintenance costs
- Roof-mounted, frees space in machinery room
- Minimal costly roof penetrations
- No expensive three-phase upgrade
- Lowest whole-life cycle costs